Hygrothermal Behavior of Thin-Walled CLT Folded Plate Envelopes under Intermittent Heating Regimes

Authors

  • Muhammed Emin Akyurek Department of Architecture, Faculty of Engineering and Natural Sciences, Istanbul Sabahattin Zaim University, Istanbul, Türkiye Author
  • İbrahim Agah Tastemir Department of Interior Architecture and Environmental Design, Faculty of Engineering and Natural Sciences, Istanbul Sabahattin Zaim University, Author

DOI:

https://doi.org/10.38027/jsalutogenic_vol5no1_6

Keywords:

Cross Laminated Timber (CLT), Folded Plate, Building Physics, Barkat Prototype, Wooden Structures

Abstract

Current building physics regulations, such as TS 825, prescribe heavy insulation based on continuous-heating assumptions. Yet, the hygrothermal consequences of the fluctuating regimes of periodically used buildings remain insufficiently characterized, particularly for thin-walled Cross-Laminated Timber (CLT) envelopes. This study evaluates the hygrothermal performance of the "Barkat Folded Plate" CLT system under a measured periodic-use scenario by triangulating exploratory field observations, steady-state digital calculation (Ubakus, Glaser method), and 1/1 scale dynamic testing. Observations in periodically heated mosques of Istanbul’s Fatih district showed indoor temperatures of 14–17°C rather than the regulatory 20–22°C; these data defined the boundary conditions for Simplified Hot Box experiments (15-hour night cycle, ΔT ≈ 17°C) on three stratification strategies. The diffusion-open Type-1 released moisture (−12 g), acting as a hygroscopic buffer; the bitumen-sealed Type-2 gained +15 g, confirming vapor-trap behavior while remaining far below the 20% fiber-saturation threshold associated with biological degradation; the hybrid Type-3 buffered +14 g within the timber without interstitial condensation. Within this single-cycle experimental scope, the findings indicate that diffusion-open and vapor-retarded timber sections manage periodic moisture loads more adaptively than heavily insulated, diffusion-closed assemblies, suggesting that envelope requirements for periodic-use functions may merit differentiation rather than uniform prescription.

Downloads

Download data is not yet available.

References

Alhawari, A., & Mukhopadhyaya, P. (2022). Construction and calibration of a unique hot box apparatus. Energies, 15(13), 4677. https://doi.org/10.3390/en15134677

Alqahtani, S., Ali, H. M., Ali, H., Farukh, F., & Kandan, K. (2023). Development of affordable hot box calorimeter to determine the U-value of inhomogeneous building material. Journal of Materials Research and Technology, 25, 6492–6502. https://doi.org/10.1016/j.jmrt.2023.07.032

American Society of Heating, Refrigerating and Air-Conditioning Engineers. (2023). ANSI/ASHRAE Standard 55-2023: Thermal environmental conditions for human occupancy.

ASTM International. (2019). ASTM C1363-19: Standard test method for thermal performance of building materials and envelope assemblies by means of a hot box apparatus. ASTM International.

Akyürek, M. E. (2024). A topological and technological transformation moel of Mimar Sinan's mosques to the present. Journal of Islamic Architecture, 8(1), 91–105. https://doi.org/10.18860/jia.v8i1.23694

Akyürek, M. E., & Taştemir, İ. A. (2026). Functional adaptation and building envelope performance in contemporary timber folded plate structures. In M. Nikoofam & A. Mobaraki (Eds.), Abstract proceedings of the 9th International Conference of Contemporary Affairs in Architecture and Urbanism (ICCAUA 2026) (p. 3). Alanya University.

Barbaresi, A., Bovo, M., Santolini, E., Barbaresi, L., Torreggiani, D., & Tassinari, P. (2020). Development of a low-cost movable hot box for a preliminary definition of the thermal conductance of building envelopes. Building and Environment, 180, 107034. https://doi.org/10.1016/j.buildenv.2020.107034

Brown, W. C., & Stephenson, D. G. (1993). A guarded hot box procedure for determining the dynamic response of full-scale wall specimens—Part I. ASHRAE Transactions, 99(1), 632–642.

Burch, D. M., Licitra, B. A., & Zarr, R. R. (1990). A comparison of two test methods for determining transfer function coefficients for a wall using a calibrated hot box. Journal of Heat Transfer, 112(1), 35–42. https://doi.org/10.1115/1.2910361

Buri, H. U., & Weinand, Y. (2008). Origami—Folded plate structures, architecture. In Proceedings of the 10th World Conference on Timber Engineering (Vol. 4, pp. 2008–2015).

Deutsches Institut für Normung. (2014). DIN 4108-3: Thermal protection and energy economy in buildings—Part 3: Protection against moisture subject to climate conditions—Requirements and directions for design and construction. DIN.

International Organization for Standardization. (1994). ISO 8990:1994: Thermal insulation—Determination of steady-state thermal transmission properties—Calibrated and guarded hot box.

Köymen, E. and Akyürek, M. E. (2026) 'A parametric design method for the wooden Turkish triangle plated structure (Barkat) model', Nexus Network Journal, 28, pp. 249-270. https://doi.org/10.1007/s00004-025-00856-6

Robeller, C., & Weinand, Y. (2015). Fabrication-aware design of timber folded plate shells with double through tenon joints. In J. Thomsen, M. Tamke, C. Gengnagel, B. Faircloth, & F. Scheurer (Eds.), Robotic Fabrication in Architecture, Art and Design 2014 (pp. 161–174). Springer. https://doi.org/10.1007/978-3-319-04663-1_11

Sánchez-Calderón, I., Rojo-Fuente, A., Martín-de-León, J., Rodríguez-Pérez, M. Á., & Bernardo, V. (2026). Reduced-scale hot box design and validation for rapid thermal conductivity evaluation of insulating materials. Polymer Testing, 157, 109141. https://doi.org/10.1016/j.polymertesting.2026.109141

Shen, Z., Brooks, A. L., He, Y., Shrestha, S. S., & Zhou, H. (2021). Evaluating dynamic thermal performance of building envelope components using small-scale calibrated hot box tests. Energy and Buildings, 251, 111342. https://doi.org/10.1016/j.enbuild.2021.111342

Trgala, K., Pavelek, M., & Wimmer, R. (2019). Energy performance of five different building envelope structures using a modified guarded hot box apparatus: Comparative analysis. Energy and Buildings, 195, 116–125. https://doi.org/10.1016/j.enbuild.2019.04.036

Türk Standardları Enstitüsü. (2008). TS 825: Binalarda ısı yalıtım kuralları [Thermal insulation requirements for buildings]. Türk Standardları Enstitüsü.

Zhao, X., Mofid, S. A., Al Hulayel, M. R., Saxe, G. W., Jelle, B. P., & Yang, R. (2019). Reduced-scale hot box method for thermal characterization of window insulation materials. Applied Thermal Engineering, 160, 114026. https://doi.org/10.1016/j.applthermaleng.2019.114026

Downloads

Published

2026-09-03

How to Cite

Akyurek, M. E., & Tastemir, İ. A. (2026). Hygrothermal Behavior of Thin-Walled CLT Folded Plate Envelopes under Intermittent Heating Regimes. Journal of Salutogenic Architecture, 5(1), 106-123. https://doi.org/10.38027/jsalutogenic_vol5no1_6